PRODUCTS - Surgical Glove
Maxitex Neuro PF
   
  A Glove So Thin that it Seems Like
You Aren’t Wearing Anything
   
 
A Microsugeon's Dream Come True
The microsurgeon relier on unrestricted fine finger movements for small vessel anastomosis, microneural, microtubular and ophthalmic surgeries. Maxitex Neuro protects the surgeon's hands and at the same time fulfill this requirement and keep the hands of the surgeons free from cramps even after long hours.

Optimal Fit = Zero Fatigue
The Neuro's softness and elasticity permit it to fit perfectly over the surgeos hands, reducing stress and eliminating fatigue on the fingers.

Enhanced Grip For Those Delicate Microsurgical Instruments
The microtextured surface provides and enhanced grip level which provides firm assurance to the user that there will not be any slippage of the instruments.

Incredible Donning And Wearing Experience
The unique multi-layer polymer coating in the glove presents an incredible donning experience for the user. The softness and high sensitivity of the fingers allow the user to focus on the microcopic procedures without distraction. The unique tan colour reduces secondary glare from the focusing lights in the Operating Theatre.

   
 
Solid reasons to swi tch to
MAXITEX NEURO
INCREASED SAFETY
  + 100% electronically tested
+ Powder free
IMPROVED COMFORT
  + Supe rior so ftness
+ Anatomical design
USER FRIENDLY
  + Microtextu red for grip
+ Easy Donning
+ Durable over long hours of
   continuous wear
+ Tan colour reduces seconda
   ryglare from focusing lights
SENSITIVITY
  + Imp roved m aterial formulation for
   extra tactile sensitivitity
+ Optimal grip for full range of
   delicate surgical procedures
   
 
Technical Specification (EN)
Specification EN Recommendation MAXITEX NEURO
Force at break >12N Typically 14N
Powder Content Unspecified <2.0 mg/glove
Water Soluble Protein Residue Unspecified Typically 30 µg/dm2
Length Min 250 mm to 280 mm
(size dependent)
Min 295 mm
Thickness at palm Unspecified 0.21 mm ± 0.02 mm
   
 
Technical Specification (ASTM)
Specification ASTM D 3577-01
Recommendation
MAXITEX NEURO
Tensile Strength Before : 24 MPa min
After : 18 MPa min
Before : 26 MPa min
After : 20 MPa min
Ultimate Elongation Before : 750% min
After : 560% min
Before : 800% min
After : 700% min
Water Soluble Protein Residue < 200 µg/dm2 < 50 µg/dm2
Powder Content < 2.0 mg/glove < 1.5 mg/glove
   
 
Ordering Information
Size Reorder# Packing info
5.5 85-154-1
8 dispenser boxes of 25 pairs each per shipping carton - or -
5 dispenser boxes of 40 pairs each per shipping carton
6 85-154-2
6.5 85-154-3
7 85-154-4
7.5 85-154-5
8 85-154-6
8.5 85-154-7
9 85-154-8
   
  MAXITEX NEURO complies with the following standards:
 
ASTM D 3577
United States of America
EN 455 Part 1, 2 and 3 European Community
ISO 10282 International Organization of Standardization
AS / NZS 4179 Australia / New Zealand
AAMI 1984 Association of American Medical Industry
ISO 11137 International Organization of Standardization
   
  click here to view product brochure
 
Page 1 Page 2